Isolated Multi-CH data LOGGER GL860

eyecatch-gl860-en_GL860_en

For more information of GL860, please download the detailed catalog.

Isolated Multi Channel Data Logger GL860 & 4 Terminals

  • 4 types of input terminals lineup including 30CH for the first time!
  • Expandable from 20ch to max. 200ch, enabling measurement of various phenomena.
  • Compatible with remote control service G-REMOTE.
  • 6 new features:
    Faster sampling interval, Memory loop functions, CH copy function, Alarm history, Inter-CH operation, Modbus communication
  • Wireless measurement from your PC is available with the optional wireless LAN unit.

All Channel Isolated / Universal Input, Standalone Multi-Channel

Voltage, temperature, and humidity can be selected for each input channel.
Use EU scaling for other measurement parameters.

Measure voltage

Supports wide operating range (from 20 mV to 100 V)

Measure temperature

Thermocouple: K, J, E, T, R, S, B, N, C(old W:WRe5-26)
RTD*: Pt100・JPt100・Pt1000(IEC751)
(only 3 wire type is supported)
*Please use B-565 for connecting the RTD

Measure current (4 -20 mA)

Shunt resistor (250Ω) is available as an option.
Equipped with a dedicated 1-5V range for the measurement range

Shunt resistance 250Ω (B-551)

*Cannot be used with the screwless terminal

Measure humidity

A humidity sensor is available as an option.
Power for the sensor is also supplied from the main unit.
Equipped with a dedicated humidity range

Humidity sensor (B-530)

Digital I/O port available

Digital I / O can be used by connecting an optional I / O cable.

Input/Output cable (B-513)

Logic/Pulse inputs (4 channels)

Logic: No-voltage contact (A contact, B contact, NO, NC) ,Open collector, Voltage input (H.L decision)
Pulse: 3 types of selections (Rotation / Quantity count / Instantaneous) per channel

<Alarm output: 4ch>

Alarm conditions can be set for each input channel.

Signal output from outputs 1 to 4 is possible in the event of an alarm.

Flexible Options with 4 Terminals

4 types of terminals including high withstand voltage B-565 are lined-up.
Select the terminal that best suits your measurement application.

Terminal Specification Comparison


WITHSTAND HIGH-VOLTAGE
HIGH-PRECISION TERMINAL
(B-565)

30CH SCREW LESS
INPUT TERMINAL

(B-563SL-30)

20CH SCREW
INPUT TERMINAL

(B-563)

20CH SCREWLESS
INPUT TERMINAL

(B-563SL)
Number of input channels20ch30ch20ch20ch
Input terminal typeM3 screw-typeScrewlessM3 screw-typeScrewless
Input methodPhoto MOS relay scanning system
All channels isolated, balanced input
Measurement ranges ※1Voltage20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50, 100 V, 1-5 V F.S.
TemperatureThermocouples:K, J, E, T, R, S, B, N, C (W: WRe5-26)
RTD (only 3 wire type is supported) : Pt100, JPt100, Pt1000(IEC751)(* RTD cannot be connected.)
Temperature range: 100°C, 500°C, 2000°C (In the case of Fahrenheit: 150°F, 750°F, 3000°F)
Humidity0 to 100% (Optional humidity sensor B-530 is required)
Maximum permissible input voltageBetween +/– terminals20mV to 2V range (60Vp-p)
5V to 100V range (110Vp-p)
Between input terminal/input terminal600Vp-p60Vp-p
Between input terminal/GND300Vp-p60Vp-p
Withstand voltageBetween input terminal/input terminal600Vp-p350Vp-p 1 minute
Between input terminal/GND2300VACrms 1 minute350Vp-p 1 minute
Voltage measurement accuracy±(0.05%ofF.S.+10μV)±0.1% of F.S.
Operating environment0 to 45℃
Dimensions(*including GL860)240×166×52.5mm (exclude protrusion)240×158×52.5mm (exclude protrusion)
Weight(*including GL860)1035g (exclude AC adapter & battery)1010g(exclude AC adapter & battery)

*Please refer to the user manual for the measurement accuracy of each terminal.

Maximum input voltage

B-565
< Between +/– terminals (A) >
– Maximum input voltage: 60Vp-p (Range of 20mV to 2V)
110Vp-p (Range of 5V to 100V)
< Between input terminal/input terminal (B) >
– Maximum input voltage: 600Vp-p
– Withstand voltage: 600Vp-p
< Between input terminal/GND (C) >
– Maximum input voltage: 300Vp-p
– Withstand voltage: 2300Vp-p at 1 minute

B-563SL-30 / B-563 / B-563SL
< Between +/– terminals (A) >
– Maximum input voltage: 60Vp-p (Range of 20mV to 2V)
         110Vp-p (Range of 5V to 100V)
< Between input terminal/input terminal (B) >
– Maximum input voltage: 60Vp-p
– Withstand voltage: 350Vp-p at 1 minute
< Between input terminal/GND (C) >
– Maximum input voltage: 60Vp-p
– Withstand voltage: 350Vp-p at 1 minute

Channel Expansion of Analog Signal Input Port

Expandable up to 200 channels.

Example

20ch / 30ch

40ch or more (up to 200ch)

Example of channel expansion

Number of channels20ch30ch40ch50ch100ch200ch
GL860111111
Connection cable for extension terminal
(B-567-05/B-567-20)
1111
Base unit for input terminal
(B-566)
2247
20ch terminal*1
(B-565/B-563/B-563SL)
12121
30ch terminal*1
(B-563SL-30)
1126

*1. When using B-565 with other terminals,
Withstand voltage: lower withstand voltage will be applied
Accuracy: depends on the terminal

The input terminal and GL860 can be extended by using the connection cable for extension terminal (50cm / 2m)

*If the measurement is affected by noise, slow down the sampling interval.

CH copy function is useful for multi-channel measurements

Copy settings such as input, range, filter, EU, etc. at once.
The setup can be done simply by selecting a channel, greatly reducing the man-hours required.
Trigger and alarm settings can also be copied

Maximum Sampling Interval of Up to 5ms

Up to 5ms sampling speed is achievable when limiting the number of channels in use.

Sampling Interval5ms10ms20ms50ms100ms250ms500ms1s
Number of channels124102050100200
MeasuringVoltage / Humidity
Temperature

Built-in 8GB Flash Memory with SD Card Support

Example of recording time (data size: 2GB)

Sampling Interval5ms10ms50ms100ms200ms500ms1s10s
GBD format15 days24 days47 days54 days108 days270 days366+ days366+ days
CSV format1 day3 days8 days11 days22 days55 days111 days366+ days

*Figures are approximate. File size of captured data is 2GB in GBD or CSV file format on this chart.
5ms: 1ch, 10ms: 2ch, 20ms: 4ch, 50ms: 10ch

Ring capture function

The most recent data is saved when the memory is configured in ring memory mode. (Number of capturing data is 1000 to 2000000 points)

Relay capture function

Data is continuously saved to multiple files up to 2GB without losing any data until capturing is stopped when the memory is configured in the relay mode.

Memory loop function

In addition to the existing relay capture function, the oldest file is automatically deleted before memory capacity runs out.

Hot-swapping the SD memory card

収録中のSDメモリカード交換機能

SD card can be replaced during data capturing when the sampling interval is 100ms or slower.
*When the wireless LAN is installed, the SD memory card cannot be inserted into the SD CARD slot.

Back up recording data

The data file can be created periodically for purpose of backing up data while recording it, and the file is automatically transferred to another storage device on the unit or FTP server on the network.

Backup interval: 1, 2, 6, 12, 24 hour(s)
Backup file destination: SD memory card or FTP server
Data file format: GBD (binary) or CSV (text)

  • The CSV format is available with firmware version 1.43 or rater.
    • Available sampling speed is the 100 ms or slower when using the CSV format.
    • When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available.
    • The storage device specified as the recording destination of the measurement data can not be set as the transfer destination of the backup file.
    • When backup is enabled and data file format is specified with CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.

Data file verification

It is a function to check the integrity of the data file when replaying the data file. It compares check-sum generated from the data file and recorded check-sum. When two check-sums do not match, the data file may be corrupted or has been changed by someone. The check-sum code is recorded into the file when data file is created by the GL unit.

  • Check-sum code is added to normal data recording file and also file created for backup, ring or relay recording. Adding check-sum is available for data files created in GBD format. When the recorded data file is converted and saved using GL100_240_840-APS or GL-Connection software, the check-sum code will not match.
  • This function is available with firmware version 1.43 or rater.

Multiple PC Interfaces Depending on Measurement Environment

Connection to your PC can be made via USB, wireless LAN or wired LAN.
*Optional B-568 is required for wireless LAN connection. The USB connection is a common A-B type cable.

Wireless connection with PC using Optional Wireless LAN unit (B-568)

*Optional Wireless LAN unit is available in limited region.

Wireless LAN option enables the wireless communication with the other devices.

Access Point enables direct connection to PCs and smart devices without a router.
Station enables connection to a wireless LAN router. Depending on the environment, data can be checked and e-mails can be received with remote PCs and smart devices via the Internet.

Wired connection with PC by Ethernet (10BASE-T / 100BASE-TX)

One-to-one connection with a PC or multiple connections via a HUB are possible.

Modbus/TCP

Data recorded by GL860 can be transferred to PLC via Modbus communication.
Recording start/stop control of GL860 is available from PLC. For more information on Modbus communication, please apply us for the SDK.

New service “G-REMOTE” *Additional charge for use.

Remote control and data capture can be easily performed using a web browser from anywhere with an Internet connection.
The recorded data can be backed up to a dedicated cloud server.

Useful Functions

Useful functions

  • Alarm output function
  • Alarm history function
  • Improved Inter-CH calculation
  • AUTO span
  • USB drive mode
  • 3 Types of power source

Operability improvements

  • Accelerated Web server function
  • Simplified waveform setup
  • Hide unnecessary menus
  • Display HELP QR Code
  • Improved visibility (Improved MENU tree)

Application Software

For PC

  • GL28-APS
    The application software connects GL series to PC. It performs setting, recording, and managing the captured data

The high-performance software

  • GL-Connection
    Connect GL series and PC via LAN / USB to manage recording data.

Specifications

GL860 Specifications
ItemDescription
Number of analog inputsMaximum 200ch available for 1 terminal(20ch/30ch) or extension unit
External input/
output  ※1
InputTrigger or Sampling (1 channel), Logic/Pulse (4 channels)
Voltage range :0 – +24V(common ground)  
Input signal: No-voltage contact (a-contact, b-contact, NO, NC), Open collector, Voltage input
OutputAlarm (4ch)
Output signal: Open collector (pull-up to 5V by 10kΩ resistor)
Sampling interval5ms – 1h(5ms – 50ms is available for voltage and humidity, Number of channels is limited, external※1
TIME / DIV1s – 24h
Trigger functionRepeat actionOff・On
Trigger typeStart: Data capture starts when a trigger is generated.
Stop: Data capture stops when a trigger is generated.
Trigger setting(Start / Stop)
Off, Level, Alarm, External, Time, Date, Week
Alarm functionAlarm judgment modeDetection method: Level, Edge
Analog channel judgment mode: H (↑), L (↓), Window In, Window Out
Logic channel judgment mode: H (↑), L (↓)
Pulse channel judgment mode: H (↑), L (↓), Window In, Window Out
Calculation channel judgment mode: H (↑), L (↓), Window In, Window Out
Pulse inputMeasurement modeRotation count (RPM) mode
Accumulating count mode
Instant count mode
Maximum number of pulse inputsMaximum input frequency : 50kHz
Maximum number of count : 50kC/sampling (16-bit counter)
PC I/FUSB2.0 (Hi-speed), Ethernet (10BASE-T / 100BASE-TX), Wireless LAN(using B-568 option) 
* B-568 is available in limited region.
Storage
device
InternalBuilt-in 8GB Flash Memory *2
External *3One SD card slot (Support SDHC memory card, up to 32GB) *2*3
Saved contentsSetup conditions
Measured data
Screen copy
Operating environment0 to 45 ºC, 5 to 85 % RH
(0 to 40°C when operated in batteries/15 to 35°C when a battery is charging)
Power supplyAC adapterAC100 – 240V / 50 – 60Hz
DC inputDC8.5 – 24V (Max. 26.4V)
Battery pack *Optional itemDC7.2V (2875mAh) (*Two packs can be mounted)
Power consumption36VA or lower (When using the AC adapter, the LCD is on, During
recharging battery, AC100V)
Vibration- tested conditionsEquivalent to Equivalent to Automobile parts Type 1 Class A Buzzer

*1. Input/Output cable for GL (option B-513) is required.
*2. Each recorded file is limited to 2GB.
*3. When the wireless LAN (B-568, optional item) is installed, the SD memory card cannot be inserted into the SD CARD slot.

Input Terminal Specifications
Software specifications for PC
ItemDescription
Model nameGL28-APS
Supported OSWindows 11 (64bit) / 10 (64bit/32bit)
FunctionsControl the GL series, Real-time data capture, and Data format conversion
Number of groupsMax. 4 groups
Number of CHs per 1 groupDepends on connected modules
Maximum number of channels1000 ch maximum
Settings controlAMP settings, capture settings, trigger/alarm settings, report settings, others
Recording dataReal-time data (CSV, GBD Binary)
Data in Internal memory or SD memory card (CSV, GBD binary)
DisplayAnalog waveforms, logic waveforms, pulse waveforms, digital values
Display modesY-T View, Digital View, X-Y View between Cursors (only during replay)
File conversionBetween cursors, All data
Monitor functionsAlarm monitor enables sending of email to the specified address
Statistic/HistoryDisplays maximum, minimum and average values during measurement
Report functionEnables creation of daily or monthly files
Wireless LAN unit B-568 (option) specifications
ItemDescription
Model numberB-568* Available in limited regions.
Communication methodWireless communication
InstallationMounted in SD CARD slot
* When the wireless unit is inserted, the SD memory card cannot be inserted into the SD CARD slot.
Wireless LAN standardIEEE802.11b / g / n
FunctionControl from PC, data transfer to PC, control and data transfer from smartphone/tablet
For access point: Local control and transfer are possible.
For station: In addition to local, remote control and transfer using G-REMOTE is also possible.
Communication range: Approx. 40 m
Communication range depends on the obstacles and the surrounding environmental conditions.
WPS: Push button method / PIN method
Encryption function: WEP64, WEP128, WPA-PSK/WPA 2-PSK (TKIP/AES)
WPA/WPA2 and TKIP/AES are automatically selected.
Humidity Sensor B-530 (option) Specifications
ItemDescription
Allowable temperature range–25 to +80°C
Allowable humidity range0 to 100% RH
Relative humidity measurement accuracy±3% RH (5 to 98% RH at 25°C)
MethodCapacitance method
Relative humidity measurement accuracy
(5 to 98%)
Measurement environmentMeasurement accuracy
0 – 10℃±5% RH
1 – 20℃±4% RH
20 – 30℃±3% RH
30 – 40℃±4% RH
40 – 50℃±5% RH
50 – 60℃±6% RH
60 – 70℃±7% RH
70 – 80℃±8% RH
Measurement accuracy at 60°C or more is a reference value.
Response time15 sec. (90% response when membrane filter is installed)
Sensor output0 to 1 VDC
External dimensionsφ14 × 80 mm (excluding cable)
Cable length3m
Sensor power sourceDC+5V – +16V
Power consumptionapprox. 4 mA

*Only one B-530 can be connected to GL860

Dimensions

GL860 External Dimensions (When B-565 & B-568 are attached)

Scale: mm
Tolerance: ±3mm

GL860 External Dimensions (When B-563SL-30 & B-568 are attached)

*Scale: mm
Tolerance: ±3mm

GL860 External Dimensions (When B-563 & B-568 are attached)

*Scale: mm
Tolerance: ±3mm

GL860 External Dimensions (When B-563SL & B-568)

  • Scale: mm
    Tolerance: ±3mm

GL860 Terminals

  • WITHSTAND HIGH-VOLTAGE HIGH-PRECISION TERMINAL (B-565) / Extension Terminal Base (B-566)
  • 30CH SCREW LESS INPUT TERMINAL (B-563SL-30) / Extension Terminal Base (B-566)
  • 20CH INPUT TERMINAL (B-563) / Extension Terminal Base (B-566)
  • 20CH SCREW LESS INPUT TERMINAL (B-563SL) / Extension Terminal Base (B-566)
  • Extension Terminal Base (B-566)
  • When connecting two Extension Terminal Bases (B-566)
  • Scale: mm
    Tolerance: ±3mm

Accessories

Standard Accessories
ItemDescription
Quick Start Guide1
AC adaptorAC100 – 240V, 50/60Hz,  Power supply cord for each area
Options
ItemModel number
20ch Withstand high-voltage high-precision terminalB-565
30CH screwless terminalB-563SL-30
20CH screw terminalB-563
20CH screwless terminalB-563SL
Base unit for input terminalB-566
Input terminal coverB-588
Connection cable for extension terminal (50cm) B-567-05
Connection cable for extension terminal (2m) B-567-20
Wireless LAN unit*1 (Available in limited region.)B-568
Battery packB-573
Bracket for DIN rail (GL860 main unit)B-570
Bracket for DIN rail for B-566B-540
Input/output cable for GLB-513
DC drive cableB-514
Shunt resistorB-551-10
AC power adapter *2ACADP-20

*1. When the wireless LAN is installed, the SD memory card cannot be inserted into the SD CARD slot.
*2. AC adaptor for replacement

Calibration-related documents (Production Data)
ItemCode
TEST CERTIFICATEB-TEST
TRACEABILITY CHARTB-TRACE
CALIBRATION CERTIFICATEB-CAL

*The data of documents ordered at the time of product purchaseare as of manufacture. Additional fee will be required to order documents with the latest data.