Important announcement – End of support information for Graphtec Pro Studio / Plus, Cutting Master 4 MORE

Firmware for GL7000 download

Software License Agreement

It is required to review the following license agreement before the software is downloaded. We will be deemed that the customer has to agree to the terms and conditions of the license agreement when the software had been downloaded by the customer. Please note that it is not possible to download or use the software if the customer does not agree to it.

Downloading Files

Ver.2.18 (Latest version)

Date of updated13 Oct, 2021
Supported ProductsGL7000
Downloading filesSoftwareGL7000_FU(v218).zip (4,956KB)

Ver.1.60

Date of updated3 Sep, 2018
Supported ProductsGL7000
Downloading filesSoftwareGL7000_FU(v160).zip (4,676KB)

Revision History

Ver.2.18

  1. Changed the maximum number of pulse CHs that can be recorded in the SSD module when the SSD module (GL7-SSD) and the logic/pulse module (GL7-L/P) are installed.
    At 1us sampling interval: 8ch (no change)
    At 2us sampling interval: 16ch => 8ch
    At 5us sampling interval: 32ch => 16ch
    Sampling interval 10us or more: 32ch to (no change)
  2. Corrected Korean notation in message window when replacing SD card during recording.

Ver.2.17

  1. Added a description of C-type thermocouple to thermocouple TC-W.
  2. Fixed the problem that when recording with the GL-Connection PC software, the GL-Connection PC recording also stops as the media capacity of GL7000 becomes full and stops recording.

Ver.2.16

  1. Fixed the problem that in the voltage value was offset when changing to the voltage range with the sensor set to resistive thermometer (RTD) in the temperature input.
  2. Fixed the problem that when the range was set to 1-5V and the input was set to something other than voltage before switching back to the voltage, the initial span value was automatically set to ±2.500V. (+1.000 – +5.000V is correct)
  3. Fixed the problem that the :FILE:CD and :FILE:MD commands resulted in an error when a Kanji character containing 0x7c in the character code exists in the path.
  4. Fixed the problem with the :FILE:LIST? command, where the file size in the list was blank if the file size was 0 byte.

Ver.2.15

  1. Fixed the problem that when switching the logic pulse input, the waveform signal of the one not selected may also be displayed.
  2. Fixed the problem that when the recording destination is changed in GL-Connection, the changes are not saved in GL7000.
  3. Fixed the problem that a file error occurs when the timing of the recording file being switched in the Relay capture function coincided with the timing of ending the recording by Stop trigger function.

Ver.2.14

  1. Fixed the problem that the calibration information of TEDS-compliant load cell sensors manufactured by TEAC could not be read correctly.

Ver.2.13

  1. Fixed the problem that some client software could not log in when accessing the FTP server of GL7000.
  2. Fixed the problem that disk full message was displayed when recording started with a 32GB SD memory card and the number of valid CHs was a few.

Ver.2.12

  1. Fixed the problem that opening the cursor movement menu during playback in the FFT and XY screens may cause system down.
  2. Fixed the problem that ”rated output” was displayed as ”rated capacity” in the setting menu of the strain sensor of the DC strain module (GL7-DCB).

Ver.2.11

  1. Improved the sensor setting of the charge module (GL7-CHA) range not to change if there is the same range in the range setting. Also, if there is no same range, the close range will be selected.

Ver.2.10

  1. Added backup function in CSV file format recording.
  2. Fixed the problem that the sampling of the GBD file automatically saved in the event RAM for dual sampling is the current sampling.
  3. Fixed the problem that only half of the time can be played back when recording to SSD module with 2ms sampling and relay capture function is on.

Ver.2.02

  1. Fixed the problem of displaying incorrect values when showing all data with a recording capacity of 4GB on the display at once.

Ver.2.01

  1. Fixed the problem that the rated output was displayed smaller than the actual value when the rated output of the module was set to μST (1×10-6) in the strain sensor setting of the DC strain module (GL7-DCB).
  2. Added “kN” to the unit of strain sensor.

Ver.2.00

  1. Added following new features to GL7000.
    1) Dual-Sampling Feature
    2) High-speed file transfer (when using software GL-Connection)
    3) Microphone input function for charge module (GL7-CHA)
    4) Improved operability of setting the DC strain module (GL7-DCB)
    5) Function menu feature

Ver.1.60

  1. Supported connection to the remote monitoring system, GRM-ONE Series.
  2. Fixed the problem that the value on the measured value side of the scaling setting is not retained when the range is changed in the charge type of acceleration unit, charge type RMS, amplifier built-in type, and amplifier built-in type RMS of the acceleration unit.

Ver.1.56

  1. Stabilized data transfer via FTP during high-speed recording to the SSD module.
  2. Improved recording start time delay when recording repeatedly with repeat interval set.

Ver.1.55

  1. Fixed the problem that the touch panel sometimes reacts without being touched when the display unit (GL7-DISP) is installed.

Ver.1.54

  1. GL7-DCB
    Fixed the problem that the unit display of the strain sensor setting was not initialized when the CH was changed using the “Previous CH” and “Next CH” keys.
  2. Fixed the problem that the amplifier unit sometimes could not be recognized properly.

Ver.1.52

  1. Fixed the problem that the operation specified within the pulse trigger range was outside the range.
  2. Fixed the problem that GL-Connection sometimes stopped when many implemented CHs were connected to GL-Connection.
    *GL-Connection must also be upgraded to Ver. 1.90 or later.
  3. Added selectable units for inputting units such as EU.

Ver.1.51

  1. Fixed the problem that in Relay capture, the file name does not switch and overwrites the same file.
    (This bug is only in Ver. 1.50)

Ver.1.50

  1. Fixed the problem that the receive buffer would run out and communication would stop when using a slow throughput line in LAN communication.
  2. Fixed the problem that depending on the Relay capture settings, the memory was consumed each time the file switches, causing occasional disk errors.

Ver.1.49

  1. Fixed the problem that the alarm was randomly activated when turning on the power with the alarm being set.

Ver.1.48

  1. Fixed the problem that only the last 10 seconds of data was saved when recording was started with the sample interval set to 1ms to 50ms and the recording destination set to either the built-in flash, SD card, or expansion SSD. (This bug is only in Ver. 1.47)

Ver.1.47

  1. Fixed the problem that the “\” mark could not be entered in the backup folder settings and subfolders could not be created in the backup destination.
  2. Fixed the problem that the span was sometimes incorrect when scaling was set to On in GL7-CHA.
  3. Fixed the problem that could not secure 10 minutes replacement time when replacing the SD card in slow sampling speed.
  4. Fixed the problem that when the most significant digit of the calculated value of [the strain sensor’s rated output] times [calibration factor] was approximately 5 to 9 for the GL7-DCB, the number was displayed 10x in playback.
  5. Changed to display a message if an error occurred during the initialization of the modules when turning on.

Ver.1.46

  1. Fixed the problem that sampling could not be set via I/F command when the recording destination is built-in RAM. (This bug is only in Ver. 1.45)

Ver.1.45

  1. Added Relay capture function that switches files every 2GB to continue recording.
    *When controlling with PC software GL-Connection, GL-Connection Ver. 1.62 or later is required.
    For details on the relay capture function, please refer to the user’s manual (GL7000-UM-105).
    GL7000-UM-105 can be downloaded from this site.

Ver.1.44

  1. Web server function supports IE11.
  2. Fixed the problem that the key operation of the touch panel was not possible on the remote operation screen of the Web server function when the display language setting was French.

Ver.1.43

  1. Fixed the problem that only the last 20,000 data were saved when saving over 20,000 data in external sampling.

Ver.1.42

  1. Fixed the problem that the backup fails when setting the backup destination to USB flash memory and changing it while recording. (No problem with data being recorded.)
  2. Fixed to display the address received from DHCP instead of the fixed IP address shown in the menu when the IP address is automatically received.
  3. Fixed the problem that the with the Charge module that the scaling value was set to the default value depending on the operating procedure.
  4. Fixed the problem that timestamps after USB replacement are abnormal for both CSV / GBD when sampling is slower than 1min.

Ver.1.41

  1. Changed the factory setting value of bridge voltage from 1V to 2V at the DC strain module.
  2. Changed the factory setting value of the filter from Off to 1 kHz at the DC strain module.
  3. Fixed the problem that the span of the waveform display changed immediately after changing the bridge voltage in the DC strain module when the input setting is the strain sensor. (It was back to normal span at the start of the recording.)
  4. Changed to automatically playback at all sampling speeds when recording in the main unit’s RAM.
    (Until V1.40, automatic playback is performed only when samples are less than 1ms)
  5. Corrected German translations.

Ver.1.40

  1. Supported Voltage output module (GL7-DCO).
    When using a Voltage output module (GL7-DCO), upgrade to this version or later.

Ver.1.30

  1. Supports Charge module (GL7-CHA).
    When using a Charge module (GL7-CHA), upgrade to this version or later.

Ver.1.20

  1. Supports DC Strain Module (GL7-DCB).
    When using a DC Strain Module (GL7-DCB), upgrade to this version or later.
  2. Added FFT calculation function.

Ver.1.11

  1. Support High Voltage Module (GL7-HV).
    When using a High Voltage Module (GL7-HV), upgrade to this version or later.
  2. Fixed the problem in which the module was misrecognized in rare cases when the power was turned on.

Ver.1.00

  1. Initial version