Compact Data Logger GL100 series
Best Choice for Easy and Quick Recording
GL100 is a data logger that can measure a variety of phenomena with simple settings because it automatically recognizes the sensor type by just connecting the sensor to it.
GL100 supports wireless LAN.
You can wirelessly connect to GL100 from a PC or smart device, check data at a distance from GL100, and remotely monitor via the Internet.
The application software comes standard for PCs and smart devices, so you can use it in different ways depending on your usage environment and purpose.
- GL100 are using the Wireless LAN (WLAN) of the IEEEE802 standards. Area that can use it is limited by the Wireless Telegraphy Act in the region.
Expand the Input Module to Accommodate a Wide Variety of Measurements
Dual port adapter connects up to two modules for simultaneous interface
- It is not able to connect two sensors of the same type.
Temperature & Humidity sensor (GS-TH) input module specifications (Limited stock)
Item | Description | |
---|---|---|
Type of measurement | Actual measuring | Temperature and Humidity |
Calculated value | Dew-point temperature and Accumulated temperature (The temperature will be accumulated during it is higher or lower than the reference temperature.) | |
Method of measurement | C-MOS sensor | |
Measuring range | Temperature | -20 to 85 °C |
Humidity | 0.0 to 100.0 % RH | |
Accuracy | Temperature | -20 ≤ TS < 0: ± 0.8 °C 0 ≤ TS ≤ 60: ± 0.5 °C 60 < TS ≤ 85: ± 0.8 °C |
Humidity | at 25 °C Measuring 0 to 10 % RH: ± 10% RH Measuring 10 to 20 % RH: ± 8% RH Measuring 20 to 80 % RH: ± 5% RH Measuring 80 to 90 % RH: ± 8% RH Measuring 90 to 100 % RH: ± 10% RH | |
Response | Temperature, Humidity: Approx. 100 seconds (Time to reach 63%, at 25 °C and air flow 1 m/s) * It varies by environment condition. | |
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Unit of temperature measurement | Switchable °C and °F | |
Water resistance | Protect by waterproof filter at the sensing part | |
Operating environment | Within temperature and humidity measurement range (When sensor is attached directly to the GL100, it is the same specifications as the GL100.) | |
External dimension [W x D x H] | Approx. 15 x 45 x 10 mm (exclude protrusion) | |
Weight | Approx. 14 g |
Acceleration & Temperature sensor (GS-3AT) input module specifications DISCONTINUED
Item | Description | |
---|---|---|
Type of measurement | Tri-axial acceleration (X-, Y-, Z-axis) and Temperature | |
Measuring range | Acceleration | ±2 G (20m/s2), ±5 G (50m/s2), ±10 G (10m/s2) |
Temperature | -10 to 50 °C (using C-MOS sensor) | |
Accuracy | Acceleration | ±2 % of F.S. (including non linearity) |
Temperature | -10 ≤ TS < 50: ± 1.0 °C | |
Response (acceleration measurement) | 0 Hz to 100 Hz | |
Measuring mode | Memory, or Direct mode | |
Memory capacity | 16, 32, 64, 128 k Samples (for memory mode) | |
Pre-trigger | 10, 25, 50, 100 % of selected memory capacity, and OFF (function is available for memory mode) | |
Sampling interval | Memory mode: 5, 10, 20, 50, 100 ms Direct mode: 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Calculation function (in Direct mode) | Function: The data is captured in every 5ms interval, and then the result of calculation between selected interval will be saved. Type of calculation: Average, Peak, RMS, or OFF (selected one value will be saved) | |
Unit of temperature measurement | Switchable °C and °F | |
Offset adjustment function | OFF, ON (sets the static acceleration value of current to zero) | |
Dustproof and waterproof | IP54 | |
Length of cable | Approx. 200 mm | |
Operating environment | Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) | |
External dimension [W x D x H] | Approx. 51 x 36 x 20 mm (exclude protrusion) | |
Weight | Approx. 64 g |
Carbon dioxide (CO2) sensor (GS-CO2) input module (Limited stock)
Item | Description | |
---|---|---|
Type of measurement | Carbon dioxide concentration | |
Method of measurement | NDIR (Non Dispersive Infra-red) | |
Measuring range | 0 to 9999 ppm | |
Measuring accuracy | ±0.5 % of reading + 30 ppm (in range of 0 to 5000 ppm) | |
Response | 3 minutes or less | |
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes (Sensing of carbon dioxide is done at interval of 2 seconds or slower. When sampling is selected to 0.5 or 1 second, the same value is recorded in each time and then value is updated every 2 seconds.) | |
Length of cable | Approx. 200 mm | |
Operating environment | Temperature: 0 °C to 50 °C Humidity: up to 80 % RH (non condensed) | |
External dimension [W x D x H] | Approx. 66 x 100 x 25 mm (exclude protrusion) | |
Weight | Approx. 99 g |
Illuminance & Ultraviolet sensor (GS-LXUV) input module DISCONTINUED
Item | Description | |
---|---|---|
Type of measurement | Actual measuring | Illuminance and UV intensity |
Calculated value | Accumulated illuminance and Accumulated UV intensity | |
Measuring range | Illuminance | 0 lx to 200 k lx |
UV intensity | 0 to 30 mW/cm2 | |
Measuring accuracy | Illuminance | ±5 % at 25 °C (Temperature characteristic: 5 % at 10 °C to 40 °C) |
UV intensity | ±5 % at 25 °C (Temperature characteristic: 5 % at 10 °C to 40 °C) | |
Response | 1 ms or less | |
Accumulating function | Illuminance | 0 to 99999 k lxh (Accumulated value is reset by starting the data recording or pressing the QUIT key.) |
UV intensity | 0 to 99999 mW/cm2h (Accumulated value is reset by starting the data recording or pressing the QUIT key.) | |
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Length of cable | Approx. 200 mm | |
Operating environment | Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) | |
External dimension [W x D x H] | Approx. 46 x 66 x 19 mm (exclude protrusion) | |
Weight | Approx. 65 g |
Voltage & Temperature Input Terminal (GS-4VT) input module DISCONTINUED
Item | Description | |
---|---|---|
Type of measurement | Analog voltage or Temperature, Logic (signal pattern) or Pulse (instant or accumulated count) | |
Number of channel | Voltage/Temperature: 4 channels (measurement type for channels can each be separately selected) Logic/pulse: 4 channels (measurement type for channels can be selected as set of 4 channels) | |
Input method of voltage/temp. | Scans by the photo-MOS-relay, all channels isolated input | |
Measuring range of voltage | 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V F.S. and 1-5V F.S. | |
Measuring accuracy | 0.15 % of F.S. | |
Input impedance | 1 M ohms | |
Maximum input voltage | Between positive (“+”) and negative (“-“) input terminal: 60 V Between negative (“-“) terminal of channels: 60 V Between negative (“-“) terminal of channel and “GND”: 60 V | |
Withstand voltage | Between negative (“-“) terminal of channels: 350 V p-p (1 minute) Between negative (“-“) terminal of channel and “GND”: 350 V p-p (1 minute) | |
Measuring range of temperature | Thermocouple: K type -200 °C to 1370 °C, T type -200 °C to 400 °C | |
Measuring accuracy | K type -200 ≤ TS ≤ -100 °C: ± (0.05% of reading + 2.0 °C) -100 < TS ≤ 1370 °C: ± (0.05% of reading + 1.0 °C) T type -200 ≤ TS ≤ -100 °C: ± (0.1% of reading + 1.5 °C) -100 < TS ≤ 400 °C: ± (0.1% of reading + 0.5 °C) Reference Junction Compensation (R.J.C.): ± 0.5 °C | |
Burnout checking | Displaying warning when Thermocouple has failed | |
Unit of temperature measurement | Switchable °C and °F | |
Input of Logic/Pulse | Input signal: Voltage or Dry contact signal Voltage input: 0 to +24V (common ground) Dry contact signal: Relay or Solid state relay Threshold voltage: Approx. +2.5V, Hysteresis: Approx. 0.5V (Status of the signal is changed in the 2V and the 2.5V.) | |
Measuring rage of Pulse | ・Instant count: up to 200 counts/sampling interval ・Accumulated count: up to 65535 counts (Accumulated value is reset by starting the data recording or pressing the QUIT key.) ・Max. input frequency : 400Hz | |
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Length of cable | Approx. 200 mm | |
Operating environment | Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) | |
External dimension [W x D x H] | Approx. 46 x 66 x 36 mm (exclude protrusion) | |
Weight | Approx. 85 g |
Thermistor Sensor Input Terminal (GS-4TSR) input module (Limited stock)
Item | Description | |
---|---|---|
Type of measurement | Temperature, Logic (signal pattern) or Pulse (instant or accumulated count) | |
Number of channel | Temperature: 4 channels (measurement type for channels can each be separately selected) Logic/pulse: 4 channels (measurement type for channels can be selected as set of 4 channels) | |
Input method of temperature | Scans by the photo-MOS-relay, all channels non-isolated input | |
Temperature sensor | Thermistor (optional) | |
Measuring range | Temperature: -40 to 120 °C (varies by the type of sensor) (Sensor GS-103AT-4P: -40 to 105 °C, GS-103JT-4P: -40 to 120 °C) | |
Measuring accuracy | • GL100 main body -40 ≤ TS < 0 °C: ± 0.7 °C 0 ≤ TS ≤ 35 °C: ± 0.2 °C 35 < TS ≤ 70 °C: ± 0.4 °C 70 < TS ≤ 120 °C: ± 1.0 °C • Thermistor sensor (GS-103AT-4P or GS-103JT-4P) Typical ± 0.4 °C | |
Unit of temperature measurement | Switchable °C and °F | |
Input of Logic/Pulse | Input signal: Voltage or Dry contact signal Voltage input: 0 to +24V (common ground) Dry contact signal: Relay or Solid state relay Threshold voltage: Approx. +2.5V, Hysteresis: Approx. 0.5V (Status of the signal is changed in the 2V and the 2.5V.) | |
Measuring rage of Pulse | ・Instant count: up to 200 counts/sampling interval ・Accumulated count: up to 65535 counts (Accumulated value is reset by starting the data recording or pressing the QUIT key.) ・Max. input frequency : 400Hz | |
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Length of cable | Approx. 200 mm | |
Operating environment | Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) | |
External dimension [W x D x H] | Approx. 46 x 66 x 36 mm (exclude protrusion) | |
Weight | Approx. 83 g |
AC Current sensor Adapter (GS-DPA-AC) input module & AC Current sensor specifications DISCONTINUED
Item | Description | |
---|---|---|
Type of measurement | Actual measuring | Current (using optional AC current sensor) |
Calculated value | Power, Accumulated power (Electric energy) | |
Type of sensor | Clamp-on current probe (optional) | |
Application circuit | Single-phase two-wire, Single-phase three-wire, or Three-phase three-wire | |
Number of sensor | Two (2) sensors are able to connect (using the same type of sensor and the power system) | |
Method of measurement | Scans channels (sensors), Non-isolated input, using RMS converter | |
Measuring range | 50, 100, 200 A RMS (varies by the sensor) | |
Applicable frequency | 50 or 60 Hz | |
Measuring accuracy | ±2 % of full sale ± 1 digit (at temperature 23 °C, and within rated current and frequency) | |
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Length of cable | Approx. 200 mm | |
Operating environment | Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) | |
External dimension [W x D x H] | Approx. 46 x 66 x 27 mm (exclude protrusion) | |
Weight | Approx. 55 g |
AC Current Sensor
Item | Description DISCONTINUED | |
---|---|---|
GS-AC50A | Rated measuring current: 50 A AC (Length of cable to adapter is approx. 200 mm) | |
GS-AC100A | Rated measuring current: 100 A AC (Length of cable to adapter is approx. 200 mm) | |
GS-AC200A | Rated measuring current: 200 A AC (Length of cable to adapter is approx. 200 mm) |
Check the Data in Multiple Method
Direct connection (peer-to-peer) with no LAN connection
Local area network (LAN) with no Internet connection
Local area network (LAN) with Internet connection
Application Software
For PC (GL100_240_840-APS)
General purpose application software will continue to have the ability to view in Y-T chart, waveform, and digital values. It is able to be also controlled the GL100 in real-time.
For Smart device (GL-Connect)
General purpose application software has the ability to view in Y-T chart and digital values. The displayed information will be refreshed by request. The simple settings of GL100 are able to control.