Isolated Multi-CH data LOGGER GL860
For more information of GL860, please download the detailed catalog.
Isolated Multi Channel Data Logger GL860 & 4 Terminals
- 4 types of input terminals lineup including 30CH for the first time!
- Expandable from 20ch to max. 200ch, enabling measurement of various phenomena.
- Compatible with remote control service G-REMOTE.
- 6 new features:
Faster sampling interval, Memory loop functions, CH copy function, Alarm history, Inter-CH operation, Modbus communication
- Wireless measurement from your PC is available with the optional wireless LAN unit.
All Channel Isolated / Universal Input, Standalone Multi-Channel
Voltage, temperature, and humidity can be selected for each input channel.
Use EU scaling for other measurement parameters.
Measure voltage
Supports wide operating range (from 20 mV to 100 V)
Measure temperature
Thermocouple: K, J, E, T, R, S, B, N, C(old W:WRe5-26)
RTD*: Pt100・JPt100・Pt1000(IEC751)
(only 3 wire type is supported)
*Please use B-565 for connecting the RTD
Measure current (4 -20 mA)
Shunt resistor (250Ω) is available as an option.
Equipped with a dedicated 1-5V range for the measurement range
Shunt resistance 250Ω (B-551)
*Cannot be used with the screwless terminal
Measure humidity
A humidity sensor is available as an option.
Power for the sensor is also supplied from the main unit.
Equipped with a dedicated humidity range
Humidity sensor (B-530)
Digital I/O port available
Digital I / O can be used by connecting an optional I / O cable.
Input/Output cable (B-513)
<Logic/Pulse inputs (4 channels)>
Logic: No-voltage contact (A contact, B contact, NO, NC) ,Open collector, Voltage input (H.L decision)
Pulse: 3 types of selections (Rotation / Quantity count / Instantaneous) per channel
<Alarm output: 4ch>
Alarm conditions can be set for each input channel.
Signal output from outputs 1 to 4 is possible in the event of an alarm.
Flexible Options with 4 Terminals
4 types of terminals including high withstand voltage B-565 are lined-up.
Select the terminal that best suits your measurement application.
Terminal Specification Comparison
WITHSTAND HIGH-VOLTAGE HIGH-PRECISION TERMINAL (B-565) | 30CH SCREW LESS INPUT TERMINAL (B-563SL-30) | 20CH SCREW INPUT TERMINAL (B-563) | 20CH SCREWLESS INPUT TERMINAL (B-563SL) | |||||||
Number of input channels | 20ch | 30ch | 20ch | 20ch | ||||||
Input terminal type | M3 screw-type | Screwless | M3 screw-type | Screwless | ||||||
Input method | Photo MOS relay scanning system All channels isolated, balanced input | |||||||||
※1 | Measurement rangesVoltage | 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50, 100 V, 1-5 V F.S. | ||||||||
Temperature | Thermocouples:K, J, E, T, R, S, B, N, C (W: WRe5-26) | |||||||||
RTD (only 3 wire type is supported) : Pt100, JPt100, Pt1000(IEC751) | (* RTD cannot be connected.) | |||||||||
Temperature range: 100°C, 500°C, 2000°C (In the case of Fahrenheit: 150°F, 750°F, 3000°F) | ||||||||||
Humidity | 0 to 100% (Optional humidity sensor B-530 is required) | |||||||||
Maximum permissible input voltage | Between +/– terminals | 20mV to 2V range (60Vp-p) 5V to 100V range (110Vp-p) | ||||||||
Between input terminal/input terminal | 600Vp-p | 60Vp-p | ||||||||
Between input terminal/GND | 300Vp-p | 60Vp-p | ||||||||
Withstand voltage | Between input terminal/input terminal | 600Vp-p | 350Vp-p 1 minute | |||||||
Between input terminal/GND | 2300VACrms 1 minute | 350Vp-p 1 minute | ||||||||
Voltage measurement accuracy | ±(0.05%ofF.S.+10μV) | ±0.1% of F.S. | ||||||||
Operating environment | 0 to 45℃ | |||||||||
Dimensions(*including GL860) | 240×166×52.5mm (exclude protrusion) | 240×158×52.5mm (exclude protrusion) | ||||||||
Weight(*including GL860) | 1035g (exclude AC adapter & battery) | 1010g(exclude AC adapter & battery) |
*Please refer to the user manual for the measurement accuracy of each terminal.
Maximum input voltage
B-565
< Between +/– terminals (A) >
– Maximum input voltage: 60Vp-p (Range of 20mV to 2V)
110Vp-p (Range of 5V to 100V)
< Between input terminal/input terminal (B) >
– Maximum input voltage: 600Vp-p
– Withstand voltage: 600Vp-p
< Between input terminal/GND (C) >
– Maximum input voltage: 300Vp-p
– Withstand voltage: 2300Vp-p at 1 minute
B-563SL-30 / B-563 / B-563SL
< Between +/– terminals (A) >
– Maximum input voltage: 60Vp-p (Range of 20mV to 2V)
110Vp-p (Range of 5V to 100V)
< Between input terminal/input terminal (B) >
– Maximum input voltage: 60Vp-p
– Withstand voltage: 350Vp-p at 1 minute
< Between input terminal/GND (C) >
– Maximum input voltage: 60Vp-p
– Withstand voltage: 350Vp-p at 1 minute
Channel Expansion of Analog Signal Input Port
Expandable up to 200 channels.
Example
20ch / 30ch
40ch or more (up to 200ch)
Example of channel expansion
Number of channels | 20ch | 30ch | 40ch | 50ch | 100ch | 200ch |
GL860 | 1 | 1 | 1 | 1 | 1 | 1 |
Connection cable for extension terminal (B-567-05/B-567-20) | – | – | 1 | 1 | 1 | 1 |
Base unit for input terminal (B-566) | – | – | 2 | 2 | 4 | 7 |
20ch terminal*1 (B-565/B-563/B-563SL) | 1 | – | 2 | 1 | 2 | 1 |
30ch terminal*1 (B-563SL-30) | – | 1 | – | 1 | 2 | 6 |
*1. When using B-565 with other terminals,
Withstand voltage: lower withstand voltage will be applied
Accuracy: depends on the terminal
The input terminal and GL860 can be extended by using the connection cable for extension terminal (50cm / 2m)
*If the measurement is affected by noise, slow down the sampling interval.
CH copy function is useful for multi-channel measurements
Copy settings such as input, range, filter, EU, etc. at once.
The setup can be done simply by selecting a channel, greatly reducing the man-hours required.
Trigger and alarm settings can also be copied
Maximum Sampling Interval of Up to 5ms
Up to 5ms sampling speed is achievable when limiting the number of channels in use.
Sampling Interval | 5ms | 10ms | 20ms | 50ms | 100ms | 250ms | 500ms | 1s | |
Number of channels | 1 | 2 | 4 | 10 | 20 | 50 | 100 | 200 | |
Measuring | Voltage / Humidity | ● | ● | ● | ● | ● | ● | ● | ● |
Temperature | – | – | – | – | ● | ● | ● | ● |
Built-in 8GB Flash Memory with SD Card Support
Example of recording time (data size: 2GB)
Sampling Interval | 5ms | 10ms | 50ms | 100ms | 200ms | 500ms | 1s | 10s |
GBD format | 15 days | 24 days | 47 days | 54 days | 108 days | 270 days | 366+ days | 366+ days |
CSV format | 1 day | 3 days | 8 days | 11 days | 22 days | 55 days | 111 days | 366+ days |
*Figures are approximate. File size of captured data is 2GB in GBD or CSV file format on this chart.
5ms: 1ch, 10ms: 2ch, 20ms: 4ch, 50ms: 10ch
Ring capture function
The most recent data is saved when the memory is configured in ring memory mode. (Number of capturing data is 1000 to 2000000 points)
Relay capture function
Data is continuously saved to multiple files up to 2GB without losing any data until capturing is stopped when the memory is configured in the relay mode.
Memory loop function
In addition to the existing relay capture function, the oldest file is automatically deleted before memory capacity runs out.
Hot-swapping the SD memory card
SD card can be replaced during data capturing when the sampling interval is 100ms or slower.
*When the wireless LAN is installed, the SD memory card cannot be inserted into the SD CARD slot.
Back up recording data
The data file can be created periodically for purpose of backing up data while recording it, and the file is automatically transferred to another storage device on the unit or FTP server on the network.
Backup interval: 1, 2, 6, 12, 24 hour(s)
Backup file destination: SD memory card or FTP server
Data file format: GBD (binary) or CSV (text)
- The CSV format is available with firmware version 1.43 or rater.
• Available sampling speed is the 100 ms or slower when using the CSV format.
• When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available.
• The storage device specified as the recording destination of the measurement data can not be set as the transfer destination of the backup file.
• When backup is enabled and data file format is specified with CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.
Data file verification
It is a function to check the integrity of the data file when replaying the data file. It compares check-sum generated from the data file and recorded check-sum. When two check-sums do not match, the data file may be corrupted or has been changed by someone. The check-sum code is recorded into the file when data file is created by the GL unit.
- Check-sum code is added to normal data recording file and also file created for backup, ring or relay recording. Adding check-sum is available for data files created in GBD format. When the recorded data file is converted and saved using GL100_240_840-APS or GL-Connection software, the check-sum code will not match.
- This function is available with firmware version 1.43 or rater.
Multiple PC Interfaces Depending on Measurement Environment
Connection to your PC can be made via USB, wireless LAN or wired LAN.
*Optional B-568 is required for wireless LAN connection. The USB connection is a common A-B type cable.
Wireless connection with PC using Optional Wireless LAN unit (B-568)
*Optional Wireless LAN unit is available in limited region.
Wireless LAN option enables the wireless communication with the other devices.
Access Point enables direct connection to PCs and smart devices without a router.
Station enables connection to a wireless LAN router. Depending on the environment, data can be checked and e-mails can be received with remote PCs and smart devices via the Internet.
Wired connection with PC by Ethernet (10BASE-T / 100BASE-TX)
One-to-one connection with a PC or multiple connections via a HUB are possible.
Modbus/TCP
Data recorded by GL860 can be transferred to PLC via Modbus communication.
Recording start/stop control of GL860 is available from PLC. For more information on Modbus communication, please apply us for the SDK.
New service “G-REMOTE” *Additional charge for use.
Remote control and data capture can be easily performed using a web browser from anywhere with an Internet connection.
The recorded data can be backed up to a dedicated cloud server.
Useful Functions
Useful functions
- Alarm output function
- Alarm history function
- Improved Inter-CH calculation
- AUTO span
- USB drive mode
- 3 Types of power source
Operability improvements
- Accelerated Web server function
- Simplified waveform setup
- Hide unnecessary menus
- Display HELP QR Code
- Improved visibility (Improved MENU tree)
Application Software
For PC
- GL28-APS
The application software connects GL series to PC. It performs setting, recording, and managing the captured data
The high-performance software
- GL-Connection
Connect GL series and PC via LAN / USB to manage recording data.
Specifications
GL860 Specifications
Item | Description | |
---|---|---|
Number of analog inputs | Maximum 200ch available for 1 terminal(20ch/30ch) or extension unit | |
output ※1 | External input/Input | Trigger or Sampling (1 channel), Logic/Pulse (4 channels) Voltage range :0 – +24V(common ground) Input signal: No-voltage contact (a-contact, b-contact, NO, NC), Open collector, Voltage input |
Output | Alarm (4ch) Output signal: Open collector (pull-up to 5V by 10kΩ resistor) | |
Sampling interval | 5ms – 1h(5ms – 50ms is available for voltage and humidity, Number of channels is limited, external※1 | |
TIME / DIV | 1s – 24h | |
Trigger function | Repeat action | Off・On |
Trigger type | Start: Data capture starts when a trigger is generated. Stop: Data capture stops when a trigger is generated. | |
Trigger setting | (Start / Stop) Off, Level, Alarm, External, Time, Date, Week | |
Alarm function | Alarm judgment mode | Detection method: Level, Edge Analog channel judgment mode: H (↑), L (↓), Window In, Window Out Logic channel judgment mode: H (↑), L (↓) Pulse channel judgment mode: H (↑), L (↓), Window In, Window Out Calculation channel judgment mode: H (↑), L (↓), Window In, Window Out |
Pulse input | Measurement mode | Rotation count (RPM) mode Accumulating count mode Instant count mode |
Maximum number of pulse inputs | Maximum input frequency : 50kHz Maximum number of count : 50kC/sampling (16-bit counter) | |
PC I/F | USB2.0 (Hi-speed), Ethernet (10BASE-T / 100BASE-TX), Wireless LAN(using B-568 option) * B-568 is available in limited region. | |
device | StorageInternal | Built-in 8GB Flash Memory *2 |
*3 | ExternalOne SD card slot (Support SDHC memory card, up to 32GB) *2*3 | |
Saved contents | Setup conditions Measured data Screen copy | |
Operating environment | 0 to 45 ºC, 5 to 85 % RH (0 to 40°C when operated in batteries/15 to 35°C when a battery is charging) | |
Power supply | AC adapter | AC100 – 240V / 50 – 60Hz |
DC input | DC8.5 – 24V (Max. 26.4V) | |
ck *Optional item | Battery paDC7.2V (2875mAh) (*Two packs can be mounted) | |
Power consumption | 36VA or lower (When using the AC adapter, the LCD is on, During recharging battery, AC100V) | |
Vibration- tested conditions | Equivalent to Equivalent to Automobile parts Type 1 Class A Buzzer |
*1. Input/Output cable for GL (option B-513) is required.
*2. Each recorded file is limited to 2GB.
*3. When the wireless LAN (B-568, optional item) is installed, the SD memory card cannot be inserted into the SD CARD slot.
Input Terminal Specifications
Software specifications for PC
Item | Description |
---|---|
Model name | GL28-APS |
Supported OS | Windows 11 (64bit) / 10 (64bit/32bit) |
Functions | Control the GL series, Real-time data capture, and Data format conversion |
Number of groups | Max. 4 groups |
Number of CHs per 1 group | Depends on connected modules |
Maximum number of channels | 1000 ch maximum |
Settings control | AMP settings, capture settings, trigger/alarm settings, report settings, others |
Recording data | Real-time data (CSV, GBD Binary) Data in Internal memory or SD memory card (CSV, GBD binary) |
Display | Analog waveforms, logic waveforms, pulse waveforms, digital values |
Display modes | Y-T View, Digital View, X-Y View between Cursors (only during replay) |
File conversion | Between cursors, All data |
Monitor functions | Alarm monitor enables sending of email to the specified address |
Statistic/History | Displays maximum, minimum and average values during measurement |
Report function | Enables creation of daily or monthly files |
Wireless LAN unit B-568 (option) specifications
Item | Description |
---|---|
Model number | B-568* Available in limited regions. |
Communication method | Wireless communication |
Installation | Mounted in SD CARD slot * When the wireless unit is inserted, the SD memory card cannot be inserted into the SD CARD slot. |
Wireless LAN standard | IEEE802.11b / g / n |
Function | Control from PC, data transfer to PC, control and data transfer from smartphone/tablet For access point: Local control and transfer are possible. For station: In addition to local, remote control and transfer using G-REMOTE is also possible. Communication range: Approx. 40 m Communication range depends on the obstacles and the surrounding environmental conditions. WPS: Push button method / PIN method Encryption function: WEP64, WEP128, WPA-PSK/WPA 2-PSK (TKIP/AES) WPA/WPA2 and TKIP/AES are automatically selected. |
Humidity Sensor B-530 (option) Specifications
Item | Description | |
---|---|---|
Allowable temperature range | –25 to +80°C | |
Allowable humidity range | 0 to 100% RH | |
Relative humidity measurement accuracy | ±3% RH (5 to 98% RH at 25°C) | |
Method | Capacitance method | |
(5 to 98%) | Relative humidity measurement accuracyMeasurement environment | Measurement accuracy |
0 – 10℃ | ±5% RH | |
1 – 20℃ | ±4% RH | |
20 – 30℃ | ±3% RH | |
30 – 40℃ | ±4% RH | |
40 – 50℃ | ±5% RH | |
50 – 60℃ | ±6% RH | |
60 – 70℃ | ±7% RH | |
70 – 80℃ | ±8% RH | |
Measurement accuracy at 60°C or more is a reference value. | ||
Response time | 15 sec. (90% response when membrane filter is installed) | |
Sensor output | 0 to 1 VDC | |
External dimensions | φ14 × 80 mm (excluding cable) | |
Cable length | 3m | |
Sensor power source | DC+5V – +16V | |
Power consumption | approx. 4 mA |
*Only one B-530 can be connected to GL860
Dimensions
GL860 External Dimensions (When B-565 & B-568 are attached)
Scale: mm
Tolerance: ±3mm
GL860 External Dimensions (When B-563SL-30 & B-568 are attached)
*Scale: mm
Tolerance: ±3mm
GL860 External Dimensions (When B-563 & B-568 are attached)
*Scale: mm
Tolerance: ±3mm
GL860 External Dimensions (When B-563SL & B-568)
- Scale: mm
Tolerance: ±3mm
GL860 Terminals
- WITHSTAND HIGH-VOLTAGE HIGH-PRECISION TERMINAL (B-565) / Extension Terminal Base (B-566)
- 30CH SCREW LESS INPUT TERMINAL (B-563SL-30) / Extension Terminal Base (B-566)
- 20CH INPUT TERMINAL (B-563) / Extension Terminal Base (B-566)
- 20CH SCREW LESS INPUT TERMINAL (B-563SL) / Extension Terminal Base (B-566)
- Extension Terminal Base (B-566)
- When connecting two Extension Terminal Bases (B-566)
- Scale: mm
Tolerance: ±3mm
Accessories
Standard Accessories
Item | Description |
---|---|
Quick Start Guide | 1 |
AC adaptor | AC100 – 240V, 50/60Hz, Power supply cord for each area |
Options
Item | Model number |
---|---|
20ch Withstand high-voltage high-precision terminal | B-565 |
30CH screwless terminal | B-563SL-30 |
20CH screw terminal | B-563 |
20CH screwless terminal | B-563SL |
Base unit for input terminal | B-566 |
Input terminal cover | B-588 |
Connection cable for extension terminal (50cm) | B-567-05 |
Connection cable for extension terminal (2m) | B-567-20 |
Wireless LAN unit*1 (Available in limited region.) | B-568 |
Battery pack | B-573 |
Bracket for DIN rail (GL860 main unit) | B-570 |
Bracket for DIN rail for B-566 | B-540 |
Input/output cable for GL | B-513 |
DC drive cable | B-514 |
Shunt resistor | B-551-10 |
AC power adapter *2 | ACADP-20 |
*1. When the wireless LAN is installed, the SD memory card cannot be inserted into the SD CARD slot.
*2. AC adaptor for replacement
Calibration-related documents (Production Data)
Item | Code |
TEST CERTIFICATE | B-TEST |
TRACEABILITY CHART | B-TRACE |
CALIBRATION CERTIFICATE | B-CAL |
*The data of documents ordered at the time of product purchaseare as of manufacture. Additional fee will be required to order documents with the latest data.