What is the fastest sampling interval (recording period)?

The fastest speed is 5ms, and the number of input channels is 1CH.

The number of measurement CHs and settable sampling intervals are shown below.

If data fluctuates due to noise, adjust the sampling interval at which the digital filter is enabled.

Number of measurement CHsSampling interval that can be setSampling interval at which digital filter is enabled
1CH5ms or slower50ms or slower
2CH10ms or slower125ms or slower
3 to 4CH20ms or slower250ms or slower
5CH50ms or slower250ms or slower
6 to 10CH50ms or slower500ms or slower
11 to 20CH100ms or slower1s or slower
21 to 40CH200ms or slower2s or slower
41 to 50CH250ms or slower2s or slower
51 to 100CH500ms or slower5s or slower
101 to 200CH1s or slower10s or slower